OTO SR Pacemaker - Single-chamber pacemaker, rate-responsive אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

oto sr pacemaker - single-chamber pacemaker, rate-responsive

microport crm pty ltd - 47267 - single-chamber pacemaker, rate-responsive - oto sr pacemaker is single-chamber rate responsive pacemaker. it is equipped with a physiological sensor (minute ventilation) and an accelerometer to allow adaptation of pacing to suit the patient?s activity oto sr pacemaker is indicated for symptomatic paroxysmal or permanent second- or third-degree av block; symptomatic bilateral bundle branch block; symptomatic paroxysmal or transient sinus node dysfunctions with or without associated av conduction disorders; bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias; vasovagal syndromes or hypersensitive carotid sinus syndromes. rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in minute ventilation and/or activity. the device(s) are mr conditional in the 1.5t and 3t mr environment.

OTO DR Pacemaker - Dual-chamber pacemaker, rate-responsive אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

oto dr pacemaker - dual-chamber pacemaker, rate-responsive

microport crm pty ltd - 47265 - dual-chamber pacemaker, rate-responsive - oto dr pacemaker is dddr-type dual-chamber rate responsive pacemaker. it is equipped with a physiological sensor (minute ventilation) and an accelerometer to allow adaptation of pacing to suit the patient?s activity oto dr pacemaker is indicated for symptomatic paroxysmal or permanent second- or third-degree av block; symptomatic bilateral bundle branch block, symptomatic paroxysmal or transient sinus node dysfunctions with or without associated av conduction disorders; bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias, vasovagal syndromes or hypersensitive carotid sinus syndromes. dual-chamber and atrial tracking modes in patients who may benefit from maintenance of av synchrony. dual-chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and av synchrony. the device(s) are mr conditional in the 1.5t and 3t mr environment.

ENO SR Pacemaker - Single-chamber pacemaker, rate-responsive אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

eno sr pacemaker - single-chamber pacemaker, rate-responsive

microport crm pty ltd - 47267 - single-chamber pacemaker, rate-responsive - eno sr pacemaker is single-chamber rate responsive pacemaker. it is equipped with a physiological sensor (minute ventilation) and an accelerometer to allow adaptation of pacing to suit the patient?s activity eno sr pacemaker is indicated for symptomatic paroxysmal or permanent second- or third-degree av block; symptomatic bilateral bundle branch block; symptomatic paroxysmal or transient sinus node dysfunctions with or without associated av conduction disorders; bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias; vasovagal syndromes or hypersensitive carotid sinus syndromes. rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in minute ventilation and/or activity. the device(s) are mr conditional in the 1.5t and 3t mr environment.

ENO DR Pacemaker - Dual-chamber pacemaker, rate-responsive אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

eno dr pacemaker - dual-chamber pacemaker, rate-responsive

microport crm pty ltd - 47265 - dual-chamber pacemaker, rate-responsive - eno dr pacemaker is dddr-type dual-chamber rate responsive pacemaker. it is equipped with a physiological sensor (minute ventilation) and an accelerometer to allow adaptation of pacing to suit the patient?s activity eno dr pacemaker is indicated for symptomatic paroxysmal or permanent second- or third-degree av block; symptomatic bilateral bundle branch block, symptomatic paroxysmal or transient sinus node dysfunctions with or without associated av conduction disorders; bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias, vasovagal syndromes or hypersensitive carotid sinus syndromes. dual-chamber and atrial tracking modes in patients who may benefit from maintenance of av synchrony. dual-chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and av synchrony. the device(s) are mr conditional in the 1.5t and 3t mr environment.

TEO SR Pacemaker - Single-chamber pacemaker, rate-responsive אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

teo sr pacemaker - single-chamber pacemaker, rate-responsive

microport crm pty ltd - 47267 - single-chamber pacemaker, rate-responsive - teo sr pacemaker is single-chamber rate responsive pacemaker. it is equipped with a physiological sensor (minute ventilation) and an accelerometer to allow adaptation of pacing to suit the patient?s activity teo sr pacemaker is indicated for symptomatic paroxysmal or permanent second- or third-degree av block; symptomatic bilateral bundle branch block; symptomatic paroxysmal or transient sinus node dysfunctions with or without associated av conduction disorders; bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias; vasovagal syndromes or hypersensitive carotid sinus syndromes. rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in minute ventilation and/or activity. the device(s) are mr conditional in the 1.5t and 3t mr environment.

TEO DR Pacemaker - Dual-chamber pacemaker, rate-responsive אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

teo dr pacemaker - dual-chamber pacemaker, rate-responsive

microport crm pty ltd - 47265 - dual-chamber pacemaker, rate-responsive - teo dr pacemaker is dddr-type dual-chamber rate responsive pacemaker. it is equipped with a physiological sensor (minute ventilation) and an accelerometer to allow adaptation of pacing to suit the patient?s activity teo dr pacemaker is indicated for symptomatic paroxysmal or permanent second- or third-degree av block; symptomatic bilateral bundle branch block, symptomatic paroxysmal or transient sinus node dysfunctions with or without associated av conduction disorders; bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias, vasovagal syndromes or hypersensitive carotid sinus syndromes. dual-chamber and atrial tracking modes in patients who may benefit from maintenance of av synchrony. dual-chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and av synchrony. the device(s) are mr conditional in the 1.5t and 3t mr environment.

CPR3H Programming Head - Cardiac pulse generator programmer אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

cpr3h programming head - cardiac pulse generator programmer

microport crm pty ltd - 47205 - cardiac pulse generator programmer - the inductive programming head (cpr3h) is a device connected to smart touch programmer via a usb adaptor (dongle). cpr3h provides inductive telemetry communication between the smart touch programmer and implantable cardiac devices. it is delivered non-sterile. the inductive programming head must be positioned in contact with the patient skin above the pacemaker or defibrillator during programming or interrogation procedures. the cpr3h programming head is intended to provide inductive communication between the smart touch programmer tablet and the implantable cardiac devices.

Cable, <specify> אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

cable, <specify>

microport crm pty ltd - 37096 - cable, - a usb adapter (cable) which connects a programming head with the programmer tablet.

CPR4BR Telemetry Head - Implantable cardiac monitor patient programmer אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

cpr4br telemetry head - implantable cardiac monitor patient programmer

microport crm pty ltd - 47805 - implantable cardiac monitor patient programmer - cpr4br telemetry head is a device connected to smart spot transmitter via a usb y cable. cpr4br provides inductive telemetry communication between the smart spot transmitter and implantable cardiac devices. it is delivered non-sterile. the cpr4br telemetry head is intended to provide inductive communication between the smart spot transmitter and the implantable cardiac devices.

Electrocardiograph, Holter analyser, software אוסטרליה - אנגלית - Department of Health (Therapeutic Goods Administration)

electrocardiograph, holter analyser, software

microport crm pty ltd - 41651 - electrocardiograph, holter analyser, software - the myrhythm pro application communicates with the compatible devices to configure them, visualizes the electrode quality application and manages the patient connection for use in myrhythm connect software. the software is not intended for direct monitoring or diagnosis.